PA-9312/24/36/48
Power Amplifier

Output Power:
- PA-9312 : 120 Watts (RMS) at less than 1% THD
- PA-9324: 240 Watts (RMS) at less than 1% THD
- PA-9336 : 360 Watts (RMS) at less than 1% THD
- PA-9348: 480 Watts (RMS) at less than 1% THD
Voltage: Current Limiting Circuit
Thermal protection
High-pass filter
Balanced input (XLR)
GND Switch: normal or lift
230V AC/24V DC Operation
Fan Cooling
Adjustable input level from 12dB to 0dB (1V)

THERMAL PROTECTION : On detecting a thermal rise due to excessive input signals, the amplifier will automatically reduce its power and give a visual and audible alarm. In such a case the amplifier should be switched off and an engineer called to re-adjust the system.

 

PA-9312
PA-9324
PA-9336
PA-9348
Power Output
(THD 0.5%)
120W
(22V/4ohm, 25V/5.2ohm,
70V/41ohm, 100V/83ohm)
240W
(31V/4ohm, 25V/2.6ohm,
70V/21ohm, 100V/41ohm)
360W (38V/4ohm, 70V/14ohm, 100V/28ohm)
480W
Frequency Response
50Hz - 20kHz
T.H.D.
(at 1kHz Rated Output)
Less than 0.5%
HPF
-3dB at 400Hz
Signal to Noise Ratio
Better than 90dB
Input Sensitivity
/ Impedance
1V/10kohm Balanced
Input Level Adjust
-12dB - 0dB
Power Source
AC 110~240V, 50/60Hz, DC 24V
Power Consumption
300W
680W
1000W MAX
Net Weight
31lbs.
14kg
42lbs.
19kg
46lbs.
21kg
48lbs.
22kg
Dimensions
19(W) X 5.2(H) X 11(D) inches
482(W) x 132(H) x 280(D) mm

 

Owners Manual, Spec Sheet, Block Diagram, Drawing, and Large Scale Photo can be found here.